Screening of fetal congenital heart disease: the challenge continues

Luciane Alves da RochaI; Edward Araujo JúniorII; Luciano Marcondes Machado NardozzaII; Antonio Fernandes MoronII

DOI: 10.5935/1678-9741.20130048

Congenital heart disease (CHD) is the most common congenital malformation [1] in fetuses. It affects eight per 1,000 live births and is more common antenatally [2-5]. In beginning, cardiac evaluation was confined to pregnancies at increased risk of CHD, such as those with a family history of CHD or where extracardiac malformations had been detected. However, up to 86% of CHD occurs in pregnancies where there are no known high risk features [6], emphasizing the need for an effective fetal cardiac screening program for all pregnancies [7,8]. For this reason, in the mid 80's started the idea of teaching the obstetrician to assess the heart in a simplified form during routine obstetric scanning [9,10].

Four chamber view scanning became an integral part of the fetal anatomical survey in many countries by the end of the 1980s [9,10]. However, prenatal screening based on visualization of the four-chamber view has much lower sensitivity [6,11]. This is partly because the four-chamber view may appear normal in cases of many anomalies, such as transposition of the great vessels, tetralogy of Fallot, double outlet right ventricle, truncus arteriosus, pulmonary or aortic stenosis/atresia and coarctation of the aorta. Anomalies of the great vessels are associated with an abnormal four-chamber view in 30% of cases [12].

When four-chamber and great vessels view are examined, the sensitivity of ultrasound screening for congenital heart defects increases from approximately 30% to 69-83% [6,11,13]. Therefore, we support the idea of evaluation both the four-chamber view and the outflow tracts (Figure 1). Then, we could improve the rate of prenatal detection of congenital heart disease.

 

 

In 2006, the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) published a guideline in which they described the "basic" and "extended basic" cardiac ultrasound examinations [14]. The intention was to standardize the assessment and to maximize the detection of heart anomalies during the second-trimester scan (Figure 1). However, we agree that a comprehensive fetal echocardiography should be performed when heart anomalies are suspected. One of the problems to follow this guideline is the difficulty of obtaining images of the outflow tracts.

This happens because unlike the four-chamber view, the aorta and pulmonary artery do not lie in a single axis. In compliance to DeVore study [15], we state that it is necessary experienced hands to view the outflow tract. Accordingly, it is important additional training.

The development of new technologies is gaining strength as they; theoretically, facilitate the evaluation of the fetal heart exam including the outflow tracts. Four-dimensional ultrasonography (4DUS) with spatio-temporal image correlation (STIC) technology allows the acquisition of a volume dataset from the fetal heart, and displays a cineloop of a complete single cardiac cycle in motion. Moreover, STIC offers the advantage of offline assessment of cardiac structures, connections, and functions [16-18] (Figure 2).

 

 

The STIC technology has several tools to analyze all cardiac structures: dynamic multiplanar mode, render mode, omni view, M mode, volume analysis, tomographic ultrasound imaging (TUI). These are new technologies that are still in development and in study.

Despite the great efforts made so far, the STIC is still considered an additional method in echocardiography and, rarely, they are available in daily practice. There are many inherent difficulties in obtaining adequate cardiac images in a STIC [16], for example: the fetal position may vary during the exam; fetal movement during the acquisition of the volume; higher maternal body mass indices or oligohydramnios may make images more difficult and acquiring the images of the heart can be time consuming.

However, we believe that the new methods will be very useful for tracking in the future. Technology tends to advance and sensitivity of this new method will continue improving. Thereby, the 3D/4D technology allows for a more comprehensive and practical assessment of CHD in the fetus.

Antenatal screening can offer a number of benefits. The identification of CHD can facilitate early therapy and to prevent a cardiac decompensation. Other benefits include opportunities to counsel parents, to screen for co-existing abnormalities, to plan peripartum management and intrauterine intervention in some cases. In severe cases, some patients choose for termination of pregnancy. Ultimately, the increased detection rates of congenital heart disease reduce perinatal morbidity and mortality. We believe that adequate training associated with a proper use of new technologies may improve the rate of diagnose CHD.

REFERENCES

1. Lee K, Khoshnood B, Chen L, Wall SN, Cromie WJ, Mittendorf RL. Infant mortality from congenital malformations in the United States, 1970-1997. Obstet Gynecol. 2001;98(4):620-7. [MedLine]

2. Hoffman JI, Christianson R. Congenital heart disease in a cohort of 19,502 births with long-term follow-up. Am J Cardiol. 1978;42(4):641-7. [MedLine]

3. Mitchell SC, Korones SB, Berendes HW. Congenital heart disease in 56,109 births. Incidence and natural history. Circulation. 1971;43(3):323-32. [MedLine]

4. Hoffman JI. Incidence of congenital heart disease: II. Prenatal incidence. Pediatr Cardiol. 1995;16(4):155-65. [MedLine]

5. Gerlis LM. Cardiac malformations in spontaneous abortions. Int J Cardiol. 1985;7(1):29-46. [MedLine]

6. Achiron R, Glaser J, Gelernter I, Hegesh J, Yagel S. Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies. BMJ. 1992;304(6828):671-4. [MedLine]

7. Robinson JN, Simpson LL, Abuhamad AZ. Screening for fetal heart disease with ultrasound. Clin Obstet Gynecol. 2003;46(4):890-6. [MedLine]

8. Smythe JF, Copel JA, Kleinman CS. Outcome of prenatally detected cardiac malformations. Am J Cardiol. 1992;69(17):1471-4. [MedLine]

9. Allan L. Antenatal diagnosis of heart disease. Heart. 2000;83(3):367. [MedLine]

10. Allan L. Prenatal diagnosis of structural cardiac defects. Am J Med Genet Part C Semin Med Genet. 2007;145C(1):73-6.

11. Xu Y, Hu YL, Ru T, Gu Y, Yang Y, Dai CY. Importance of "Guidelines for performing fetal cardiac scan" in prenatal screening for fetal congenital heart disease. Zhonghua Fu Chan Ke Za Zhi. 2009;44(2):103-7. [MedLine]

12. Paladini D, Rustico M, Todros T, Palmieri S, Gaglioti P, Benettoni A, et al. Conotruncal anomalies in prenatal life. Ultrasound Obstet Gynecol. 1996;8(4):241-6. [MedLine]

13. Carvalho JS, Mavrides E, Shinebourne EA, Campbell S, Thilaganathan B. Improving the effectiveness of routine prenatal screening for major congenital heart defects. Heart. 2002;88(4):387-91. [MedLine]

14. International Society of Ultrasound in Obstetrics & Gynecology. Cardiac screening examination of the fetus: guidelines for performing the 'basic' and 'extended basic' cardiac scan. Ultrasound Obstet Gynecol. 2006;27(1):107-13. [MedLine]

15. DeVore GR. The aortic and pulmonary outflow tract screening examination in the human fetus. J Ultrasound Med. 1992;11(7):345-8. [MedLine]

16. DeVore GR, Falkensammer P, Sklansky MS, Platt LD. Spatio-temporal image correlation (STIC): new technology for evaluation of the fetal heart. Ultrasound Obstet Gynecol. 2003;22(4):380-7. [MedLine]

17. Viñals F, Poblete P, Giuliano A. Spatio-temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects. Ultrasound Obstet Gynecol. 2003;22(4):388-94. [MedLine]

18. Gonçalves LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen ML, Falkensammer P, et al. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. Am J Obstet Gynecol. 2003;189(6):1792-802. [MedLine]

CCBY All scientific articles published at bjcvs.org are licensed under a Creative Commons license

Indexes

All rights reserved 2017 / © 2024 Brazilian Society of Cardiovascular Surgery DEVELOPMENT BY