Article

lock Open Access lock Peer-Reviewed

3

Views

ORIGINAL ARTICLE

Hidro-dynamic flowmeter in myocardial revascularization surgery

Fabio Biscegli Jatene; Pedro C. P Lemos; Adib D Jatene

DOI: 10.1590/S0102-76381986000100008

ABSTRACT

Evaluation of blood flow in saphenous vein grafts during coronary surgery gives valuable information about myocardial perfusion and long-term by- pass patency as well. However, electronic flowmeter availability is a limiting factor because of costs and maintenance. A system was developed consisting of a connection to the arterial line, with a Y tube; one branch of the Y tube is connected to a manometer and the other one to the vein graft. Since the connection to the arterial line has a know diameter, pressure drop in the system is proportional to the flow in the graft. With previous calibration, a chart was constructed that allows instantaneous evaluation of the flow. Another advantage of the system is the selective perfusion of the area to be treated before the conclusion of the proximal anastomosis. This system is being used in our Service; it is efficient and practical.

RESUMO

A avaliação do fluxo pelas pontes de veia safena na cirurgia de revascularização do miocárdio fornece uma informação segura do aporte sangüíneo ao miocárdio, bem como da perspectiva de perviabilidade destas anastomoses a longo prazo. Contudo, em nosso meio, a disponibilidade de fluxômetros eletrônicos, habitualmente utilizados, é, por vezes, difícil, sobretudo em função de seu custo e manutenção. O sistema desenvolvido consta de um conector para a linha arterial, com saída lateral, ligado a um tubo de Y. Uma das extremidades é conectada a um manómetro e a outra, à veia safena, ao término da anastomose distal. Como a saída lateral tem diâmetro conhecido, a queda da pressão, quando se liga o sistema para aveia safena, é proporcional ao fluxo. Uma tabela obtida por calibração prévia, permite conhecer, instantaneamente, o fluxo para a artéria tratada. Outra vantagem do sistema é a irrigação seletiva para a área tratada antes da realização da anastomose proximal, situação favorável quando existem áreas severamente isquémicas. Este sistema, em uso corrente em nosso Serviço, vem provando a sua eficiência, aliada à sua praticidade e ao custo irrelevante.
Full text available only in portuguese PDF format.

REFERENCES

1. BALDERMAN, S. C.; MORAN, J. M.; SCANLON, P. J.; PIFARRÉ, R. - Predictors of late aorta-coronary graft patency: intra-operative phasic flow versus angiography. J. Thorac Cardiovasc Surg., 79: 724-728, 1980. [MedLine]

2. FitzGERALD, D. E.; FORTESCUE-WEBB, C. M.; EKESTRÖM, S.; LILJEQVIST, L.; NORDHUS, O - Monitoring coronary artery blood flow by doppler shift ultrasound. Scand. J. Thorac. Cardiovasc. Surg., 11: 119-123, 1977. [MedLine]

3. FOLTS, J. D.; KAHN, D. R.; BITTAR, N.; ROWE, G. G. - Effects of partial obstruction on phasic flow in aortocoronary grafts. Circulation, 51/52 (Supl. 1): 148-155, 1975.

4. MARCUS, M.; WRIGHT, C.; DOTY, D.; EASTHAM, C.; LAUGHLIN, D.; KRUMM, P.; FASTENOW, C.; BRODY, M. - Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans. Circ. Res., 49: 877-891, 1981. [MedLine]

5. MORAN, J. M.; CHEN, P. Y.; RHEINLANDER, H. F. - Coronary hemodynamics following aorta-coronary bypass graft. Arch. Surg., 103: 539-544, 1971. [MedLine]

6. MORAN, J. M.; BURKE, D. W.; LOEB, J. M.; ROBERTS, A. J.; SANDERS Jr., J. H.; MICHAELIS, L. L. - Accuracy in coronary graft tow measurement. Ann. Thorac Surg., 32: 506-509, 1981. [MedLine]

7. MOULDER, P.V.; TEAGUE, M. J.; MANUELE, V. J.; BRUNSWICK, R. A.; DAICOFF, G. R. - Intraoperative doppler coronary artery finder. Ann. Thorac. Surg., 24:430-432, 1977. [MedLine]

8. RENEMAN, R. S.; CLARKE, H. S.; SIMMONS, N.; SPENCER, M. P. - In vivo comparison of electromagnetic and doppler flow-meters: with special attention to the processing of the analogue doppler flow signal. Cardiovasc. Res., 7: 557-566, 1973. [MedLine]

9. SEGADAL, L. - Assessment of flow in aortocoronary grafts. Semin. in Ultrasound, CT and M.R., 6: 68-72, 1985.

10. SEGADAL, L.; MATRE, K.; ENGEDAL, H.; RESCH, F.; GRIP, A - Estimation of flow in aortocoronary graft with a pulsed ultrasound doppler meter. Thorac. Cardiovasc. Surg., 30: 265-268, 1982. [MedLine]

11. WRIGHT, C.; DOTY, D.; EASTHAM, C.; LAUGHLIN, D.; KRUMM, P.; MARCUS, M. - A method for assessing the physiologic significance of coronary obstructions in man at cardiac surgery. Circulation, 62 (Supl. 1): 111-115, 1980.

CCBY All scientific articles published at bjcvs.org are licensed under a Creative Commons license

Indexes

All rights reserved 2017 / © 2024 Brazilian Society of Cardiovascular Surgery DEVELOPMENT BY